Product Features

  • Valve Regulated Lead Acid (VRLA) Battery
  • Maintenance-Free, Absorbent Glass Mat (AGM) Technology for Efficient Gas Recombination of up to 99%
  • Pure Lead Construction and Proprietary Elements
  • Designed for High-Rate UPS, Float Service Standby Power Applications
  • Built in Accordance with IEC 61056-1/2:2012 and UL1989 Recognized (MH14533)

Application Scenarios

  • Data center UPS backup battery
  • Server room uninterruptible power supply
  • Industrial UPS high-power backup
  • Medical equipment UPS emergency power
  • Financial system UPS backup
  • Telecom room UPS backup

Product parameters

  • Model:UPS12460
  • Voltage:12 Vdc
  • Nominal Capacity:460W @5min-rate
  • Watts per Cell:74.00 (5-Min 1.67 VPC @ 25°)
  • Watts per Cell:36.83 (15-Min 1.67 VPC @ 25°)
  • Max. Charge Current:3.80 A
  • Max. Discharge Current:130 A
  • Short Circuit Current:450 A
  • Internal Resistance:16.60 mΩ
  • Terminal Type:F2 terminal (Faston Tab 250)
  • Container Material:ABS (UL 94-HB) standard, flame-retardant (94-V0) available upon request
  • Weight:2.50 / 5.51 kg / lb.
  • Length (L):150.9±2.0 / 5.94±0.08 mm / in
  • Width (W):64.8±1.0 / 2.55±0.04 mm / in
  • Height (H):98.6±1.0 / 3.88±0.04 mm / in
  • Design Life:Up to 5 years in standby service at 25°C; Eurobat (20°C): 3-5 years, Standard Commercial
  • Float Charging Voltage:13.5 - 13.8 Vdc/battery
  • Equalizing Charging Voltage:14.4 - 15.0 Vdc/battery
  • Operating Temperature:discharge -15°C to 50°C; charge/storage -15°C to 40°C

Product details

The CSB UPS12460 belongs to the UPS series, a product type of 6V and 12V top terminal VRLA-AGM batteries, with an official application area of data center uninterruptible power supplies. This series is positioned as a high-power pure lead UPS battery series built specifically for uninterruptible power supply applications. For this model, the nominal voltage is 12 Vdc, and the nominal capacity is 460W at the 5-minute rate at 9.60V per PCS @ 25°C, with cell power of 74.00 W/cell at 5 minutes 1.67 VPC @ 25°C and 36.83 W/cell at 15 minutes 1.67 VPC @ 25°C. In terms of electrical parameters, the UPS12460 has a maximum charge current of 3.80 A, a maximum discharge current of 130 A, a short-circuit current of 450 A, and an internal resistance of 16.60 mΩ. The float charge voltage is 13.5 to 13.8 Vdc/battery (25°C), and the equalizing charge voltage is 14.4 to 15.0 Vdc/battery (25°C). For self-discharge, capacity loss is less than 10% after 90 days of storage at 25°C, storage is possible for up to 6 months, a full charge is required before use, and if storage temperature exceeds 25°C, charging should be done sooner. Structurally, the battery uses valve-regulated sealed lead-acid design and absorbed glass mat technology, with gas recombination efficiency of up to 99%, and uses pure lead construction with proprietary elements. The case material is ABS (UL 94-HB), and a flame-retardant version (94-V0) is available on request. The terminal type is F2 terminal - Faston Tab 250. Dimensions are length 150.9±2.0 mm, width 64.8±1.0 mm, height 98.6±1.0 mm, and weight 2.50 kg. In terms of temperature and life, the nominal operating temperature is 25°C, the discharge temperature range is -15°C to 50°C, and the charge and storage temperature range is -15°C to 40°C. Design life reaches 5 years in float standby service at 25°C, and 3 to 5 years for Eurobat (20°C) standard commercial applications. The product is manufactured in accordance with IEC 61056-1/2:2012 and is recognized under UL1989 (MH14533). Based on the above characteristics, the UPS12460 is suitable for float standby scenarios in data center uninterruptible power supplies, designed for high-rate discharge and maintenance-free operation, and can meet the requirements of float service standby power applications for battery consistency, sealing, and gas recombination.