CSB GP1272F2 12V25W Valve-Regulated Sealed Lead-Acid Battery
The CSB GP1272F2 is a 12V 25W valve-regulated sealed lead-acid battery using AGM technology, suitable for general-purpose float standby power in security, emergency lighting, and medical equipment. Design life up to 5 years, float charge voltage 13.5-13.8V, wide operating temperature range.
Taobao store
WeChat procurement
Product Features
- Valve Regulated Lead Acid (VRLA) Battery
- Maintenance-Free, Absorbent Glass Mat (AGM) Technology for Efficient Gas Recombination of up to 99%
- Pure Lead Construction and Proprietary Elements
- Designed for Float Service Standby Power Applications
- Built in Accordance with IEC 61056-1/2:2012 and UL1989 Recognized (MH14533)
Application Scenarios
- Security alarm panel backup power
- Emergency lighting fixtures and exit signs
- Medical monitors and infusion pumps backup
- Access control and building intercom systems
- Fire alarm and linkage control panels
- Small electronic instruments and test equipment
Product parameters
- Model:GP1272F2 12V25W
- Voltage:12 Vdc
- Nominal Capacity:24.5W@15Min-rate
- Watts per Cell:48.9 (5-Min 1.67 VPC @ 25°)
- Watts per Cell:24.5 (15-Min 1.67 VPC @ 25°)
- Max. Charge Current:2.5 A
- Max. Discharge Current:130 A
- Short Circuit Current:160 A
- Internal Resistance:25.8 mΩ mΩ
- Terminal Type:F2 terminal (Faston Tab 250)
- Container Material:ABS (UL 94-HB) standard, flame-retardant (94-V0) available upon request
- Weight:1.84 / 4.06 kg / lb.
- Length (L):150.9±2.0 / 5.94±0.08 mm / in
- Width (W):64.8±1.0 / 2.55±0.04 mm / in
- Height (H):98.6±1.0 / 3.88±0.04 mm / in
- Design Life:Up to 5 years in standby service at 25°C; Eurobat (20°C): 3-5 years, Standard Commercial
- Float Charging Voltage:13.5 - 13.8 Vdc/battery
- Equalizing Charging Voltage:14.4 - 15.0 Vdc/battery
- Operating Temperature:discharge -15°C to 50°C; charge/storage -15°C to 40°C
- Note:F1 terminal is available; Max Discharge Current = 100 A
Product details
The CSB GP1272F2 is a 12V 25W valve-regulated sealed lead-acid battery belonging to the GP series of general-purpose products. It uses absorbed glass mat (AGM) technology with gas recombination efficiency up to 99%, achieving maintenance-free operation. The battery complies with IEC 61056-1/2:2012 and is certified to UL1989 (MH14533). The case material is ABS (UL 94-HB), with a flame-retardant (94-V0) version also available.
In terms of electrical parameters, the battery delivers 24.5W/cell at the 15-minute rate and 48.9W/cell at the 5-minute rate at 25°C. Maximum charge current is 2.5A, maximum discharge current is 130A, short-circuit current is 160A, and internal resistance is 25.8mΩ. Float charge voltage is 13.5-13.8Vdc/battery (25°C), and equalizing charge voltage is 14.4-15.0Vdc/battery (25°C).
The nominal operating temperature of the battery is 25°C (77°F), the discharge temperature range is -15°C to 50°C (5°F to 122°F), and the charge and storage temperature range is -15°C to 40°C (5°F to 104°F). The self-discharge rate is low, with remaining capacity over 90% after 90 days of storage at 25°C; it can be stored for up to 6 months, but must be fully charged before use, and if storage temperature exceeds 25°C it should be charged earlier.
In terms of physical specifications, the battery dimensions are length 150.9±2.0mm, width 64.8±1.0mm, height 98.6±1.0mm, and weight approximately 1.84kg (4.06 lb). The terminal type is F2 (Faston Tab 250). Design life can reach 5 years under float charge at 25°C, meeting the Eurobat standard (20°C) 3-5 year commercial-grade life.
The battery is suitable for general-purpose float standby power scenarios such as security systems, emergency lighting, and medical equipment. Its valve-regulated sealed construction ensures safety and reliability, AGM technology provides efficient gas recombination, and pure lead construction and proprietary elements enhance performance.